² 计量(liang)(liang)功效:撑持正向(xiang)、反向(xiang)有(you)功电(dian)能计量(liang)(liang),此中反向(xiang)电(dian)量(liang)(liang)计入正向(xian꧒g)电(dian)量(liang)(liang);
² 费(fei)控形式转(zhuan)换(huan)功效:电能表备(bei🐬)长途预支费(fei)和(he)本(ben)地(di)预支费(fei)功效,两种(zhong)形式能够按照办理须要随时转🌄(zhuan)换(huan);
² 充(chong)值功效:电(dian)(dian)(dian)表(biao)在本地预支费(fei)形(xing)式(shi)时,用(yong)户必(bi)须先充(chong)值后用(yong)电(dian)(dian)(🌠dian),主(zhu)动(dong)结(jie)算(suan)计费(fei)、扣费(fei),无费(fei)断(duan)电(dian)(diaᩚᩚᩚᩚᩚᩚᩚᩚᩚ𒀱ᩚᩚᩚn)(dian), 用(yong)户充(chong)值冲正余额后电(dian)(dian)(dian)表(biao)主(zhu)动(dong)合闸供电(dian)(dian)(dian);
² 退(tui)费功效(xiao):当用户搬(ban)迁时(shi),如(ru)电表内仍(reng)不足额,能够(gou)将预(yu)缴(jiao)金额退(tui)还用户,而后将电表余额主动“归(gui)零𓆏”;
² 换(huan)(huan)表功效:当某一个(ge)电表产(chan)生毛病须要(yao)改换(huan)(huan)时,可共同体系完成换(huan)(huan)表功效,记实旧表底数(shu)和新表底数(shu)并主动结算旧表数(shu)据(ju🐭)和用度;
² 长(zhang)途监控与通(t🍌ong)断(duan)电:能(neng)长(zhang)途及时监测(ce)各装备的运转状态(tai), 长(zhang)途节(jie)制(zhi)通(tong)断(duan)电,可经(jing)由过程电脑下发号令对某一个或某一些房间停止(zhi)通(tong)断(duan)电节(jie)制(zhi)。
² 恶(e)性(xing)负(fu)载(zai)限定:电能表可(ke)主动(dong)辨(bian)认恶(e𓂃)性(xing)负(fu)载(zai),呈现恶(e)性(xing)负(fu)载(zai)(大功率用电装备)后主动ꦯ(dong)拉闸断电,保证用电宁静;
² 总(zong)功率限定:电(dian)能表(biao)可完成总(zong)功率限定,当负荷跨越设(she)定的(de)最(zui)大功率阀值时,电(dian)表(biao)主动跳闸,🐻保(bao)证用(yong)💃电(dian)宁静;
² 保电(dian)功(gong)效:电(dian)能表具备保电(dian)功(gong)效,当保电(dian)功(gong)效启用(yong)后,不(bu)管何种♎情况(kuang)下电(dian)表都不(bu)会跳闸断电(dian),供特别办(ban)理情况(kuang)下利用(yong);
| 计量 | 有功电能精确度品级 | A级、B级 | |
| 丈量 | 电压 | 丈量规模 | 0.6Unom~1.2Unom |
| 电流 | 丈量规模 | Imin~1.2Imax | |
| 功率 | 丈量规模 | PQ(起动功率)~1.2Unom×1.2Imax | |
| 通讯 | 通讯接口 | 红外、RS485 | |
| 通讯规约 | DL/T 645-1997 | ||
| 通讯速度 | 1200bps | ||
| 电气 机能 | 介电强度 | 交换工频电压 | 3kV |
| 脉冲电压 | 6kV 1.2/50us | ||
| 电磁兼容 | 疾速瞬变群脉冲 | 实验品级:4级(GB/T 17626.4) | |
| 浪涌 | 实验品级:4级(GB/T 17626.5) | ||
| 静电 | 实验品级:4级(GB/T 17626.2) | ||
| 零件功耗 | ≤0.3W | ||
| 利用 情况 | 任务温度 | -25℃~+60℃ | |
| 极限任务温度 | -40℃~+70℃ | ||
| 绝对湿度 | ≤85%(极限湿度:≤95%) | ||
| 规格 | 0.25-0.5(30)A、0.25-0.5(60)A、0.5-1(80)A A级 | ||
| 0.2-0.5(30)A、0.2-0.5(60)A、0.4-1(80)A B级 | |||